em253 positioning module selection----PLC skills|PLC Applications|PLC Basics|PLC Articles

em253 positioning module selection

  

em253 bit module, the perfect coordination of speed and accuracy using a simple, precise control of the control em 253 stepper motor from the micro to the intelligent servo drive. Running fast and unfettered integration of the interface can generate 200khz pulse of the pulse signal, specify a location, speed and direction. Integrated position switch input from the central processing unit can be completed independently position control tasks. Adaptive pulse or rs422 5v DC input. Low shock can select "jerk"/s-curve function can be reduced at the start, stop and change speed and shock generated when the rear seat. Control of flexible and powerful program can be configured by the user and select the 25 profile, each profile can have up to four speed change. Absolute, relative and can be manually positioned ; distance and location of the units are set to mm, inches, degrees or number of pulses. You can choose four different reference point search mode. Simple software configuration, graphical, integrated step 7-micro/win, v 3.2 (and above) of the wizard has the following features: parametric (basic parameter settings) to create a profile to determine the positioning of the reference point search mode integrated micro/win in the control panel, easy-em253-line parameters support changes and parametric functions. Third, the positioning module em253 technical specifications 1, general specification model 6es7 253-1aa22-0xa0 module structure s7-200 expansion module input 5em em 8 output size (w ?— h ?— d) 71.2 ?— 80 ?— 62 mm Weight 190g external 11 to 30vdc power supply voltage Current consumption 5vdc 2.5w power consumption: 190ma24vdc power supply: see below configuration software step 7-micro/win, v 3.2 (and above) 2, enter the number of input features 5-point input type exchange point/source (iec type 1 Meeting Point, excluding zp) the maximum allowable input voltage    continued
   stp, rps, lmt, lmt-
   zp    surge (all inputs)
   rating    stp, rps , lmt, lmt-   zp    logic "1" signal (minimum)    stp, rps, lmt, lmt-   zp    logic "0" signal (max)    stp, rps, lmt, lmt -   zp 30 vdc
30 vdc, 20 mA, max
35 vdc, 0.5 24 vdc, 4 mA, nominal
24 vdc, 15 mA, nominal 15 vdc, 2.5 mA, minimum 3 vdc, 8.0 mA, minimum 5 vdc, 1 mA, maximum 1 vdc, 1 mA, maximum insulation (on-site to logic)
   Optical isolation (electrochemical)
   Insulation group
500 vac, 1
1 point, stp , rps and zp
2 point, lmt lmt-entered, and the delay time
   stp, rps, lmt, lmt-
   zp (countable pulse width)
0.2 milliseconds to 12.8 milliseconds, microseconds minimum user-selectable
2 value close to the two wires connecting the sensor (bero)
   allowable leakage current